Comark C9555/SIL - Waterproof Pressure Meter 0 to ¡À 2100mbar [SKU 3062865]
Previous | 3 / 4 | Next |
Comark C9555/SIL - Waterproof Pressure Meter 0 to ± 2100mbar
The Comark C9555/SIL Waterproof Pressure Meter 0 to ± 2100mbar combines high accuracy with speed of response and is designed to function between 0 to ±2100mbar, with twin inputs for gauge or differential pressure measurement.
- Pressure Measurement Range – 0 to ±2100 mBar
- Twin Inputs for Gauge or Differential Pressure
- Connections: 1/8″ BSP female
With a durable design to survive an industrial setting, it is dust and waterproof to IP67 Standard (BS EN 60529), and an optional protective rubber boot is also available.
Complete with free connectors and tubing.
Complete with free connectors and tubing.
- Selectable pressure units, PSI, mbar, Bar, inH2O, inHg, mmHg, torr, KPa, cmH2O, Kgcm-2
- Over-range indication – maximum over/under pressure 90PSI/6200mbar
- Silicone protection option for liquid pressure measurement
- Adjustable zero value
- Maximum, minimum pressure and hold function
- Averaged reading function
- Selectable auto switch off
Supplied with
Pressure Tubing and Connectors designed for use with C95xx Pressure Meters. Contains 4 x 1/8″ BSP Nylon Washers, 1.4m Polyurathane Tube SP Blue, 2 x Male Stud Coupling c/w Washer.
Technical Specifications
Name | Value |
---|---|
Pressure Measurement Range | 0 to ±2100 mBar (See manual for other ranges) |
Resolution | 0.1mBar |
Accuracy | ±0.2% of full scale (FS) at +23°C |
Repeatability | ±0.1% of full scale (FS) at +23°C |
Mean Temperature Coefficient of Reading | <0.1% per °C |
Operating Range | 0 to 50°C, 10 to 90% RH non-condensing |
Environmental Protection | IP67, BS:EN60529, IEC529 |
Battery | *9V PP3 6F22 — MN1604 UCAR9V |
125 hours (using MN1604) | |
*Non-IS Models Only. IS models must only use Zinc Chloride Battery | |
Low Battery Warning | Displays BAT just before end point of battery |
Over Pressure Indication | – – – – |
Over 9999 Reading Indication | Lowest 4 digits blink |
Connections | 1/8" BSP female |
Weight | 330gm including battery |