Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo Testo 480 - Digital Temperature, Humidity and Air Flow Meter [SKU 0563 4800] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo


testo 480 - Digital Temperature, Humidity and Air Flow Meter
 
  • High-quality optional sensors for measuring air flow, temperature, humidity, pressure, degree of turbulence, heat radiation, CO2, illumination intensity, PMV/PPD and WBGT
  • High-precision, integrated pressure sensor included
  • Pro-software for easy and efficient analysis and logging included
  • Intelligent calibration concept
Air flow measurements in ducts, temperature measurements in laboratories, humidity measurements in production, pressure difference measurements in clean rooms. The testo 480 digital temperature, humidity and air flow meter comes with a wide range of optional sensors that allow you to measure, analyse and log these and a variety of other parameters with only one device.
 
 
Product Description
 
The easy-to-use testo 480 is a high-precision digital temperature, humidity and air flow meter which allows you to measure, analyze and log all relevant ventilation and indoor air quality parameters with only one device.
 
The high-precision digital temperature, humidity and air flow meter is designed to provide independent experts, consultants, technical service providers and HVAC technicians in the field of ventilation and indoor air quality with an efficient means of carrying out all their measurements – i.e. norm-compliant setting and adjustment of air conditioning and ventilation systems in offices, residential and industrial buildings – using just one single device.
 
It is also designed to check quality parameters in production and processing quickly and reliably.
 
 
The intelligent concept behind the testo 480
 
The testo 480 has a built-in, high-precision difference pressure sensor for pitot static tube measurements and filter/clean room monitoring. There is also a wide range of high-quality optional sensors for carrying out the following measurements:

  • Air flow and volume flow (also fume cupboard measurements)
  • Temperature
  • Humidity
  • Pressure (difference and absolute pressure)
  • CO2
  • Illumination intensity
  • PMV/PPD
  • Heat radiation
  • Degree of turbulence
  • WBGT Index
The testo 480 digital temperature, humidity and air flow meter comes with a wide range of optional sensors and accessories – like the wireless testo quick printer for print outs on site – which allow you to customize your meter to suit your own pocket and meet your own needs.
 
 
State-of-the-art technology for HVAC technicians and experts
 
The testo 480 was designed to make your work more efficient and life easier. The high-quality, easy-to-use digital temperature, humidity and air flow meter can be used to measure all relevant ventilation and air conditioning parameters and carry out long-term measurements with only one device. What’s more it’s got a mammoth-size memory that can save up to 60 million measurements and a set of integrated programs that guide you through the following measurements step by step.

  • VAC measurements in compliance with EN 12599
  • Degree of turbulence measurements in compliance with EN 12599
  • PMV/PPD measurement in compliance with ISO 7730
  • WBGT measurement in compliance with ISO 7243
 
 
“Easy Climate” PC software
 
The “Easy Climate” software allows your readings to be transferred directly to a PC via a USB cable where they can then be presented, analyzed or logged. A specially developed protocol designer enables you to create protocols to suit your customers’ needs and the optional testo quick printer provides you with printouts on site.
 
 
Digital sensors and intelligent calibration concept
 
The optional testo digital sensors provide you with highly accurate results as there is no measurement inaccuracy from the meter. In addition, any deviations which are determined during calibration can be saved to the digital sensor. These deviations are compensated automatically giving you a zero error value. The intelligent sensors alert the user when the next calibration – which can be carried out by hand thereby ensuring that you always have your meter with you when you need it – is due.
 
The testo 480 digital temperature, humidity and air flow meter has a built-in, high-precision difference pressure sensor with a measuring range from -100 to +100 hPa and connection possibilities for a further three optional digital and two temperature (type K thermocouple sensors).
 
 
Delivery Scope
 
testo 480 digital temperature, humidity and air flow meter, integrated difference pressure sensor, “Easy Climate” software, power adaptor, USB cable, calibration certificate.
 
Please note: the sensors and accessories described in the product presentation above are all optional and must be ordered separately.
 
 
Technical Data
 

Temperature - Pt100
Measuring range -100 to +400 °C
Resolution 0.01 °C
 
Temperature - TC Type K (NiCr-Ni)
Measuring range -200 to +1370 °C
Accuracy ±(0.3 °C to 0.1 % of mv)
Resolution 0.1 °C
 
Humidity - Capacitive
Measuring range 0 to 100 %RH
Resolution 0.1 %RH
 
Velocity - Vane anemometer
Measuring range 0.6 to +50 m/s (vane anemometer Ø 16 mm)
0.1 to +15 m/s (vane anemometer Ø 100 mm)
Resolution 0.1 m/s (vane anemometer Ø 16 mm)
0.01 m/s (vane anemometer Ø 100 mm)
 
Velocity - Hot wire anemometer
Measuring range 0 to +20 m/s
Resolution 0.01 m/s
 
Ambient CO
Measuring range 0 to 10000 ppm CO
Resolution 1 ppm CO
 
Comfort level measurement
Measuring range 0 to +5 m/s
Resolution 0.01 m/s
 
Differential pressure (internal sensor) - Piezoresistive
Measuring range -100 to +100 hPa
Accuracy ±(0.3 Pa + 1 % of mv) (0 to +25 hPa)
±(0.1 hPa + 1.5 % of mv) (+25.001 to +100 hPa)
Resolution 0.001 hPa
 
Light
Measuring range 0 to 100000 Lux
Resolution 1 Lux
 
Absolute Pressure (internal sensor and external probe)
Measuring range 700 to 1100 hPa
Accuracy ±3 hPa
Resolution 0.1 hPa
 
General technical data
Operating temperature 0 to +40 °C
Protection class IP30
Connectable probes 2 x Temperature TC Type K, 1 x differential pressure  (internal), 3 x digital
EU-/EG-guidelines 2004/108/EG
Warranty 2 years
Battery life approx. 17 hours (hand instrument without probes, with 50 % display brightness)
Display function Colour graphic display
Power supply Rechargeable battery, plug-in mains unit for long-term measurements and charging battery
Data transfer USB cable or SD card
Memory 60,000,000 measuring values
Storage temperature -20 to +60 °C
Weight 435 g
 
 
Applications
 
Calibration of air-conditioning cabinets as per DAkkS/DKD directive 5-7
 
Monitor your air conditioning cabinet for precise temperature and humidity conditions with the testo 480 measuring instrument. The instrument protects your work and helps you to comply with quality standards by measuring with the accurate humidity probe (order no 0636 9743) and Pt100 temperature probe (order no. 0614 0073), which automatically compensate for non-conformities. It is easy to connect up to three humidity and Pt100 temperature probes at the same time. Calibrate your air-conditioning cabinet in compliance with the reference standard, with no errors. The testo 480 provides smooth management and documentation of your measurement data. 

 
Differential pressure measurement on filters
 
Air conditioning systems are equipped with filters which prevent dirt from the outside air entering the indoor air. These filters are to be inspected regularly to make sure they are still fully functional. To do this, the pressure is measured in front of and behind the filter. The result is the differential pressure. If it is too high, the filter is contaminated and needs changing. 
 
testo 480 uses the integral sensor to measure the differential pressure within the 25...25 hPa range. The differential pressure measurement is temperature-compensated for exact readings. Magnets on the rear of the instrument allow hands-free work.
 
Ensuring the process climate in clean rooms
 
testo 480 is the ideal instrument for ensuring the process climate in clean rooms. Differential pressure can be checked with the internal pressure sensor to an accuracy of +/- 0.3 Pa +1% of reading. The air temperature is measured with the accurate Pt100 probes and humidity fluctuations are monitored with an accuracy of +- 1 % rF using the precise humidity and temperature probe (order number: 0636 9743). The thermal flow probe (order number: 0635 1048) is used to check laboratory flues and measure laminar flow.
 
High precision temperature and humidity measurement
 
In many industrial processes, highly accurate and reliable measurement of humidity and temperature is required to ensure consistent quality. For example, in your production facilities or laboratory, temperature and humidity can be accurately measured to +/- 1% using the humidity and temperature probe (order number: 0636 9743). You need all physical factors of the Mollier diagram and the testo 480 will calculate them for you. With the integrated measurement programs extensive options are available for monitoring your nominal values.
 
Flow measurement in the ventilation duct using a pitot tube
 
Observance of air flows in the ventilation duct is of utmost importance for the function of the ventilation and air conditioning system. 
 
The internal differential pressure sensor of the testo 480 is used for measuring in the case of high flow velocities and very contaminated flows, and the pitot tube for an air velocity ranging from 0 to 64 m/s. The testo 480 simultaneously displays pressure, flow and volumetric flow. Magnets on the rear of the instrument allow hands-free work.
 
Our pitot tubes are available in different designs: in lengths of 350 mm to 1000 mm and diameters of 4 mm and 7 mm.
 
Measurement of indoor air quality (CO2)
 
Bad indoor air quality due to high concentrations of CO2 can cause tiredness, lack of concentration and even illness. Therefore, to ensure sufficient indoor air quality the CO2concentration is generally not to exceed 1 000 ppm. Values of 700 to 1 500 ppm can be viewed as the “reference range”.

The IAQ probe (order no. 0632 1543) is particularly suitable for monitoring indoor air quality controls. This probe can be used to record CO2, temperature and relative humidity at the same time.
 
Laboratory flue gas measurement in accordance with EN 14175
 
Use the testo 480 to measure the inflow rate and exhaust air volumetric flow rate in laboratory flues as per EN 14175. This will guarantee your customer correct positioning of the flue and efficient flue performance on site.
 
Measurement of the air and surface temperature
 
For human beings to be comfortable and perform at their best, it is crucial that the rooms they occupy are correctly air conditioned. As well as the structural conditions and personal perception, the following factors also contribute significantly to the existence of a pleasant indoor climate: the indoor air and surface temperature of walls, windows, floors and ceilings.
 
There is a great selection of TE temperature probes available for the testo 480. The surface probe (order no. 0602 0393) and air humidity probe (order no. 0636 9743) can be used to investigate dew point shortfalls and mould. 
 
Also part of the range: TC temperature probe with T-hinge measuring head and very quick response time for temperature measurements on surfaces (order no. 0614 0195).
 
Up to two temperature probes specially for measurements on pipes can be connected to the testo 480 to record and show the difference in temperature in a heating system.
 
Measurement of radiated heat
 
Thermal radiation (that is, the operative or perceived temperature) in the environment can be determined with the attachment Globe thermometer (order no. 0602 0743); this comprises a black hollow copper sphere which has the tip of a mercury thermometer at its centre. The operative temperature measured with a Globe thermometer with a 150 mm diameter preferably corresponds with people's perceived temperature to ± 0.41 K.
 
The temperature measurements in a room (air temperature and operative temperature) are to be taken in the same place and same general conditions as the measurement of indoor air velocities.
 
The optional tripod (order no. 0554 0743) secures all probes safely and conveniently, even for long-term measurements.
 
Turbulence measurement in accordance with EN 13779
 
The air velocity in rooms directly affects thermal comfort. The turbulence and draught levels can be referred to in the assessment of comfort.
 
The level of turbulence indicates the air velocity fluctuation and intensity of air flow in a room.
 
The air velocity in rooms directly affects thermal comfort. The turbulence level is given as a percentage, calculated from the mean air velocity and air temperature in rooms. The level of turbulence indicates the air velocity fluctuation and intensity of air flow in a room. There is a direct correlation between the air temperature and turbulence level.
 
The draught rate can be generally understood as the unwanted cooling of the body due to air movement. The draught rate is defined as the percentage of people who feel uncomfortable. The draught rate is also given as a percentage, calculated from the mean flow velocity, mean temperature and turbulence level.
 
The non-directional comfort probe (order no. 0628 0143) has been specially designed to measure the turbulence level in accordance with EN 13779, and to assess the draught rate. The integrated assisted measurement program in the testo 480 enables the standard-compliant measurement results to be analyzed directly in the measuring instrument. The optional tripod (order no. 0554 0743) secures all probes safely and conveniently, even for long-term measurements.
 
Precision temperature measuring in the laboratory
 
Use the new high-precision Pt100 immersion and penetration probe to carry out measurements in laboratories with an accuracy of ± 0.05 °C in the 0 to +100 °C range. 
 
The new digital precision temperature probe enables high-precision temperature measurements in liquids and pastes. After entering the calibration data in the software, your measurement will show no errors; the testo 480 can therefore be used as a working standard.
 
PMV-/PPD value measurement according to ISO 7730
 
A person's sense of well-being in a room (level of comfort) depends on a series of particular external influencing factors. For example, people are extremely sensitive towards thermal radiation caused by cold walls or windows. We also respond to draughts in a room with thermal discomfort.
 
Thermal comfort is defined by the following main influencing factors: 

  • Indoor air temperature and radiation temperature
  • Air velocity
  • Relative humidity of the indoor air
In turn, the effect of these main influencing factors on a person's sense of comfort depends on his or her (level of) activity and clothing. The international standard ISO 7730 combines all of the parameters in the PMV/PPD measurement (Predicted Mean Vote/Predicted Percentage Dissatisfied). The PMV is an index which predicts the average climate assessment value of a large group of people. The PPD Index provides a quantitative prediction of the number of people that will be dissatisfied with a certain ambient atmosphere.
 
The measurement program integrated into the testo 480 directly calculates the PMV/PPD value according to ISO 7730 using optional attachment probes. The generated diagram (link to diagram) in the measuring instrument helps you to evaluate an indoor climate quickly and objectively. The PMV/PPD measurement protocol (link to pdf) records the measurement data for you and your customers.
 
Volumetric flow measurement at the air outlet
 
Every duct inlet and outlet should only contain the volumetric flow that according to calculations is a basic prerequisite to an efficient functional system. 
 
The large vane anemometer with 100 mm diameter is ideal for measuring the volumetric flows at duct outlets (order no. 0635 9343), as it integrates the flow velocity over a larger area thereby determining disturbance from the air grille (loop method).
 
To measure the suction or blowing vents of air grilles and plate valves our volumetric flow rate funnel set is ideal (order no. 0563 4170) as is the large 100 mm vane anemometer (order no. 0635 9343) The entire volumetric flow is recorded with the aid of the funnel without the need for conversion on the basis of the flow velocity and area. This method of flow measurement is simple and reliable.
 
Take reliable measurements at ceiling outlets using the bendable, thermal flow probe (0635 1543).
 
WBGT measurement at workplaces exposed to heat as per DIN 33403 and ISO 7243
 
Use the WBGT probe (Wet Bulb Globe Temperature) to measure and monitor heat stress, e.g. in the steel industry. Measure the WBGT index in compliance with the standards. In the testo 480 this climate index is determined according to DIN 33403 and ISO 7243. Use it to ensure physical well-being in the workplace and prevent circulatory collapse, heat cramps and heat stroke.
 
Flow measurement in the ventilation duct according to EN 12599
 
Use testo 480 and the flow probes to carry out VAC grid measurements according to EN 12599 and to configure your system to make it energy-efficient. The measurement results can be presented to your customers on site in the VAC measurement protocol (link to pdf). 
 
We have the ideal flow probe for your duct measurements:

  • Probes for low, medium and high flow velocities 
  • Probe for turbulent flows 
  • Probes with non-rotatable, robust telescope. The scaling on the telescope ensures that the immersion depth is easy to read.
  • Probe for ventilation ducts with small holes 
Air temperature and humidity can also be measured with the same probe as the flow velocity if required. 
 
Selecting a suitable probe depends on the flow velocity in the ventilation duct. This can be broken down into three sub-ranges: 

  • Low flow velocities: thermal anemometers are suitable for this (order no. 0635 1543, 0635 1024, and 0635 1050)
  • Medium flow velocities: the 16 mm vane anemometer provides the best results (order no. 0635 9542) 
  • High flow velocities: the pitot tube provides the best prerequisites (see following application)
 
Humidity measurement in the VAC system according to EN 12599
 
In winter, the absolute humidity in the outside air is generally not enough to uphold the requirement of a pleasant room humidity of approx. 30% rF to 70% rF (as per DIN EN 13779) in buildings with ventilation and air conditioning systems. Therefore, air humidifiers are often used within ventilation systems.
 
To ensure that these systems function properly EN 12599 specifies that in addition to other measurement parameters, such as volumetric flow and temperature, relative humidity also has to be measured at different points within the VAC system. Typical measuring points are in front of and behind heat exchangers and humidifiers. Conversion into the required humidity units (e.g. absolute humidity) is possible with the testo 480.
 
The humidity probe (order no. 0636 9743) has the ideal size of 12 mm diameter for measurement in the ventilation duct. This probe can record relative humidity and temperature in parallel. The humidity probe can also be used to assess thermal comfort within a room.
 
Lighting measurement
 
Suitable lighting in the workplace provides workers with sufficient light to be able to perform their jobs well. It helps to prevent mistakes being made, premature tiredness setting in, and maintains alertness. 
 
testo 480 and the Lux probe (order no. 0635 0543) can be used to measure and assess luminous intensity (natural or artificial light).
 
 
Downloads
 
Product Brochures

Product brochure testo 480  (PDF, 1.7 MB)
TESTOsolutions efficient measurement and analysis of indoor climate  (PDF, 859.9 kB)
pb_testo480_de_Klimamessgerät1  (application/pdf, 714 KB)
 
Manuals

Instruction manual testo 480  (PDF, 4.3 MB)
Instruction Manual - PC-Software - Testo EasyClimate  (PDF, 3.1 MB)
Short manual testo 480  (PDF, 877.6 kB)


Video Demo


 
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in