Atago ES-421 | Digital Salt-Meter [Code 4211]
Previous | 3 / 6 | Next |
ATAGO Digital Salt Meter
Features
Why choose ATAGO?
- Fast: Results are displayed within 3 seconds.
- Easy measurement: Just press the START Key.
- Easy calibration: Clean the sensor and press the ZERO Key.
- Digital Display: No more varied readings caused by user interpretation.
- Automatic Temperature Compensation: Reliable for any samples, hot or cold.

Tried, tested, and proven features and design

Application Examples
A potato chips manufacturer
Salt is sprinkled on fried potato slices from a machine, and the amount of salt dispensed is checked and adjusted at the beginning of a production lot. In the past, we had to take samples to the lab for testing, but now we can do it right at the production line.
The ES-421 saves us time and money because it does not use reagents like titration systems. Even the disposal of the titrating reagents is not free. ATAGO's salt meter is environmentally friendly and economical.
A condiment manufacturer
We are testing sauces and dressings for salt with the
ES-421.The instrument is perfect for use at the production site because it is compact and does not use harmful chemicals.
A canned food manufacturing plant
We are using the PAL-SALT to measure the brine for canned tuna. It is easy to use and completely washable under the faucet. We liked it so much that we purchased a second unit.
More examples >>>
Measurement Method
ES-421 3 easy steps:
![]() |
![]() |
![]() |
1. Apply 2-3 drops onto the sensor section. | 2. Press the START key. | 3. Measurement value is displayed in 3 seconds. |
How to prepare samples >>>
Digital Salt-Meter ES-421
The digital salt-meter, ES-421 employs a funnel-shaped sensor section (conductivity), which measures the salt % of a sample (dilute solution of soy sauce, ketchup,mayonnaise, Worcester sauce, sqeezed juice of pickles, etc.) very small sample needed (1.0mL approx. is enough for measurement).
- Improved durability with titanium electrodes and a sample stage made out of SUS316L.
- Equipped with a backlight to produce an even brighter, easier to read display.
- Equipped with an “Offset Function.”
The concentration of the NaCl solution for calibration has been changed from 2.84%→2.50%.
Specifications
Model | ES-421 |
Cat.No. | 4211 |
Scale |
Salt concentration (g/100g) Temperature |
Measurement Method | Conductivity method |
Measurement Range | 0.00 to 10.0% |
Resolution |
0.01% for salt concentration of 0.00 to 2.99% 0.1% for salt concentration of 3.0 to 10.0% |
Measurement Accuracy |
Displayed value ± 0.05% (for salt concentration of 0.00 to 0.99%) Relative precision ± less than 5% (for salt concentration of 1.00 to 10.0%) |
Ambient Temperature | 10 to 40°C (Automatic Temperature Compensation) |
Power Supply | 006P Dry battery (9V) |
Offset feature | Yes |
Dimensions & Weight |
17×9×4cm, 220g (Main Unit only) |
Options
- NaCl Solution 2.50% (±0.05%) AB250 [*1] : RE-120250