Atago RePo-5 | Portable Refracto-Polarimeter [Code 5015]
Previous | 2 / 5 | Next |
Atago RePo-5 | Portable Refracto-Polarimeter
The RePo-5 can determine refractive index (nD)
- In addition to angle of rotation and Brix, the RePo-5 can also display the refractive index (nD) of a sample.
- The RePo-5 is ideal for quality control in various industries such as fragrances, cosmetics, or pharmaceutical.
- RePo-5 satisfies Pharmacopoeia standards.
Specifications
Model | RePo-5 |
Cat.No. | 5015 |
Scale | Angle of Rotation, Brix, Refractive index, Temperature |
Measurement Readings |
Angle of Rotation, Brix, Temperature User (Refractive index) Brix with Automatic Temperature Compensation |
Measurement Range |
Angle of Rotation : -5.00 to +5.00°(*1) Brix : 0.0 to 85.0% Refractive index : 1.3306¡«1.5050 Temperature : 15.0 to 40.0¡æ |
Display Range |
Angle of Rotation : -5.99 to +5.99° Brix : -2.0 to 86.6% Refractive index : 1.3278 to 1.5093 Temperature : 14.0 to 41.0¡æ |
Resolution |
Angle of Rotation : 0.01° Brix : 0.1% Refractive index : 0.0001 Temperature : 0.1¡æ |
Measurement Accuracy |
Angle of Rotation: ±0.1° (at 20¡æ) Brix £º ±0.2% Refractive index : ±0.0002 (at 20¡æ) Temperature: ±1¡æ |
Repeatability |
Angle of Rotation: ±0.05° (at 20¡æ) Brix £º ±0.1£¥ |
Wavelength | 589nm (near D-line) |
Temperature compensation range | Brix £º 15 to 40¡æ |
Ambient Temperature | 15 to 40¡æ |
Storage environment temperature | 0 to 65¡æ |
Light source | LED |
Sample Volume | 3mL |
Measurement Time | 12 seconds |
Power Supply | Size AAA alkaline battery x4 |
International Protection Class | IP67 |
Dimensions & Weight | 101 x 160 x 38mm, 325g (main unit only) |
(*1)These ranges are measured by the device’s 20mm light path.
These are convertible to below ranges:
-25.00°to +25.00°with a 100mm observation tube
-50.00°to +50.00°with a 200mm observation tube
Any sample that has Angle of Rotation within above ranges can be measured by RePo units
Options
- Standard liquid Repo-series : RE-99110
- MAGIC™ for RePo : RE-79000
- RePo Small Volume Adapter : RE-72093
- RePo Reduced Optical Path Adapter 5mm : RE-72094
- RePo Reduced Optical Path Adapter 5mm(Adapter only) : RE-72095
- RePo Reduced Optical Path Adapter 5mm(Glass Cell only) : RE-72096
- RePo Reduced Optical Path Adapter 10mm : RE-72097
- RePo Reduced Optical Path Adapter 10mm(Adapter only) : RE-72098
- RePo Reduced Optical Path Adapter 10mm(Glass Cell only) : RE-72099
Atago Portable Refracto-Polarimeter RePo Series
Four Points
-
2 in 1
Brix alone can only indicate the overall amount of dissolved solids in a solution. With REPO-1, it is possible to determine if a product has been adulterated by measuring the optical rotation. For example, fructose rotates light to the left while glucose rotates light to the right. If a sample has been adulterated with glucose, it will make the optical rotation readings appear more positive than a pure solution.
-
Compact size
Great portability, 10.1×16.0×3.8cm and weighs only 325g.
-
Automatically calculated scales
Press 'User' to select the desired scale: Purity, International Sugar Scale, Specific Rotation, and Concentration.
-
Measurement evaluation indicator
Measurements are evaluated against pre-set tolerance limits, and the result is indicated by green or red light. (Upper and lower tolerance limits must be set in advance to using this function)
Features
Application Examples
Sugar industries
(sugar manufactures and refineries) |
Analyzing inverted sugar syrups | Analyzing fragrances |
Honey industries
|
Measuring Method
1. Fill the sample stage up to the fill line (approx. 3mL).
|
2. Press START.
|
3. Measurement is displayed.
|