Muser Apac Sdn Bhd
V Office 2, VO2-03-12,
Lingkaran SV,
Sunway Velocity,
Jalan Peel,
55100 Kuala Lumpur,
Malaysia.
+603-2742 7468

Climet CI-570 | NextGen Portable Particle Counter

Previous 3 / 4 Next

Climet CI-570 | NextGen Portable Particle Counter Portable Particle Counters Climet Climet CI-570 | NextGen Portable Particle Counter Portable Particle Counters Climet


Download Files

Climet_CI-x70+Series_Brochure.pdf (0.97 MB)
Climet CI-570 | NextGen™ Portable Particle Counter
 
Serious Instruments for Serious Users
 
 
Smallest and lightest Industrial and Pharmaceutical Grade Particle Counter with stainless steel enclosure, and 6-channels with a built-in printer, pdf reports, and the most advanced technology ensuring the highest level of accuracy and repeatability of measurement.
 
Drop and vibration tested for industrial use.
 
In business for over 55 years, Climet has dozens of multi-jurisdictional patents in field of particle counting. Climet is a pioneer and innovator having been the first to introduce the battery powered portable particle counter (CI-500) in 1993. Since then, Climet has developed virtually every meaningful feature for portable particle counters, many of which today are considered industry standard. This includes but is not limited to high flow rates of 50 LPM, 75 LPM, and 100 LPM.  The CI-x70 Series is fully compliant with ISO 21501-4; PIC/S; FDA CGMP; EU GMP, Annex 1; ISO 14644-1/2:2015; 21 CFR Part 11, and others.
 
 
NextGen™ Technology
 
Introduced August 2017, the CI-x70 NextGen 6-Channel Portable Particle Counter offers numerous enhancements including new patent pending or patented technology. It's the smallest and lightest industrial and pharmaceutical grade particle counter, with many new user-inspired innovations including:
  • 6-channels: 0.3 µm to 10 µm, some models up to 25 µm
  • Flow Rate of 1 CFM, 50 LPM, 75 LPM, or 100 LPM
  • 21 CFR Part 11 Complaint
  • Industrial Use: 1m drop tested (14x up to 94 g's) and vibration tested (1 hour), then powered-up and passed calibration.
  • PDF (Portable Document Format) reports for ISO 14644:2015, GMP, and FS 209e with Sample Data Filtering (dates, etc.)
  • User Integrity Audit Trail
  • Display is a color LCD (cellphone-type) capacitive touch screen display (pinch to zoom, swipe to scroll)
  • Battery: Single lithium-ion for up to 6 hours of continuous operation (depending on model) - That's a 100% duty cycle with a zero count filter installed.
  • New ultra-quiet / ultra-clean blower technology
  • Network time server synchronization - First on the market!
  • Sample Data Storage - Up to a million samples or more!
  • User IDs: 100, and factory expandable!
  • Location IDs: 100, and factory expandable!
  • Programs: 100, and factory expandable!
  • Light Ring: New user-configurable status and alarms (enable/disable, 5-colors, patters, etc.)
  • Audible Tone: user-configurable multi-pitch beep on count and alarm
  • HEPA filtered exhaust factory certified to ISO Class 3
  • Fully integrated thermal printer
  • Fully integrated battery charger
  • Simplified Unit-to-Unit Cloning
  • Same laser and collection optics as the CI-x5x model providing unparalleled accuracy and repeatability
  • Only the highest quality materials used ensure long product life and up to 99.6% passing an interval calibration
  • Security: 5 - levels of user security with user authentication
  • VHP Compatible
  • Weight: Stainless Steel enclosure at only 9.4 lbs. with battery installed!
  • Dimensions 8.38" x 7.4" x 9.48" (That's only 587.9 cubic inches!) 
An energy efficient design, the CI-x70 will run longer on a single battery than the competition using a dual-battery configuration.  When comparing battery efficiencies, don't be fooled by comparisons of "nominal" or "typical" use. Climet conducts battery testing with "continuous" use (laser and blower engaged with 100% duty cycle, and with a zero-count filter installed). The single battery configuration means Climet customers will spend substantially less money over the life of the instrument on consumables, including batteries.

The CI-x70 Series is truly the next generation of particle counter, with onboard intelligence unsurpassed on the market today, it provides Climet a platform for future enhancements, and scalability to satisfy custom technical requirements.
 
 
General information
 
The CI-x70 Series are pharmaceutical industrial grade 6-channel portable particle counters that come in your choice of 1 CFM, 50 LPM, 75 LPM or 100 LPM flow rates.  Each model comes standard with an RS-232 serial interface, Ethernet TCP/IP, and USB.
 
Seamless stainless-steel enclosure simplifies cleaning and sanitation.  A completely sealed front panel display prevents biocides, IPA, and other cleaning fluids from accidently leaking into the interior of the particle counter, thus eliminating the risk of short circuit or premature catastrophic damage to the sensor. 
 
An expert in manufacturing industrial instrumentation, every new Climet instrument design is drop and vibration tested ensuring end-users can expect up to a decade (and beyond) of reliable operation. This level of ruggedized testing is unique in the industry, and ensures accidents don't turn into capital appropriation requests or expensive repair bills.  


Tested and Certified HEPA Filtered Exhaust (ISO Class 3)
 
Each particle counter deployed in the Life Science industry must have a HEPA Filtered Exhaust, or otherwise risk regulatory action (i.e., an observation, finding, etc.) due to rouge particle emissions. Over the past 50 years our own experience confirms that not all HEPA filters are created equal, and that among the more expensive and higher quality filters an average of 10% still fail a leak integrity test.  For this reason, Climet is the only manufacture of particle counters that conducts emissions tests on every new factory model, and certifies emissions to ISO Class 3. This provides an added level of assurance to end-users that their particle counters are not adding to the particle burden of their cleanroom.
 
 
Accuracy and Stability of Measurement
 
A long-earned reputation in the industry for manufacturing the most accurate particle counters, Climet particle counters have unparalleled repeatability (in metrological terms: stability or precision) of measurement.  Over 50 years of manufacturing experience and use of the highest quality materials provides users unparalleled performance. 
 
High quality materials, an expert level of engineering acumen, and a mature DFM (Design For Manufacturability) virtually eliminate short-term and long-term calibration drift. This also enhances product life cycle, offering users a decade or more of reliable use.  This is but one factor that greatly enhances Climet's reputation for providing the lowest TCO (Total Cost of Ownership). End users in regulated industries, and others of discerning taste for high precision instrumentation, exclusively sole source Climet as their preferred solution provider.
 
 
Interval Calibration Out-of-Tolerance Rates
 
Customers in regulated industries are generally required to re-calibrate their particle counters at least annually.  Depending on the process or risk assessment, more frequent interval calibration may be required. When a particle counter is out-of-tolerance (OOT) during the interval calibration, a deviation report and investigation is required in regulated industries.  Among pharmaceutical and biotechnology producers a simple failure investigation costs between $8,000 to $12,000 on average assuming no scrap or batch rejection.  This cost is difficult to calculate as it's almost all labor and  usually involves multiple departments.  It is a hidden Cost of Poor Quality (CoPQ) associated with the instrument, which few end users track. As the cost of one simple failure investigation well exceeds the initial purchase price of a particle counter, we can conclude that CoPQ is frequently the #1 cost driver.
 
Internal studies and customer Total Cost of Ownership (TCO) feedback confirms that on average when a Climet particle counter is equal to or less than 7 years old, the instrument passes its interval calibration 99.6% of the time. In a separate internal study of 2,000+ Climet particle counters, it was confirm an in-tolerance rate of 98.3%, with approximately 25% of the particle counters included in this study being 10 or more years old.  These statistics are absolutely unparalleled in the industry, and Climet uniquely provides value well beyond the simple use of the instrumentation.
 
 
Part Configurations
 
CI-570: 50 LPM, Sizes:0.3/0.5/3.0/5.0/10.0 µm, HEPA Filter, Printer, Ethernet, RS-232, USB, Battery


Technical Specifications
 
Exceeding standards and expectations. Climet uniquely manufactures our instrumentation, not to simply meet ISO 21501-4 standards, but to exceed the standard in order to meet user expectations for: (1) accuracy and stability of measurement; (2) mitigation of deviation reports and investigations; (3) ease of use; and (4) overall product quality.  These factors uniquely provide our loyal customers the lowest TCO (Total Cost of Ownership).
 
Buy From An Innovator, Not An Imitator: Climet, literally, invented the portable particle counter (1993), as well as higher flow rates of 50 LPM, 75 LPM, and 100 LPM (2005-2008).  With a long history of successfully implementing disruptive technologies, our customers can rest assured they own the highest quality instrumentation available on the market.  Every Climet particle counter is manufactured with the highest degree of engineering acumen, and incorporates one or more patented or patent pending technologies.
 
Uncompromising Quality is in our Corporate DNA. Our success is not based on quirky marketing gimmicks, but rather rock-solid instrumentation that adds personal value, and that's time-proven and built to last a decade or more.
 
Channel Sizes 0.3 μm, 0.5μm, 1μm, 3μm, 5μm, and 10μm
Size Calibration < ±10% with internal pulse height analyzer (PHA) in compliance with ISO 21501-4.
Size Resolution ±4% to ±10% typical. Substantially exceeding ISO 21501-4 of < ±15%.
Count Efficiency 50% Count Efficiency (a measure of size): < ±10% to Climet standards. Substantially exceeding ISO 21501-4 of < ±20%. 100% Count Efficiency (a measure of flow and laser alignment): < ±10%. In compliance with ISO 21501-4.
False Count Rate Equal to or better than ISO 21501-4 specifications.
Flow Rate CI-570 Series @ 50 LPM
Sample Volume Uncertainty Flow Control and internal mass flow meter ensures compliance with ISO21501 – 4 Flow Rate tolerance of ±5%.
Sample Volume is user-adjustable in cubic meters, cubic feet, or liters.
Exhaust HEPA filtered exhaust uniquely factory tested to ensure no leaks and certified to ISO Class 3 emissions.
Substantially exceeding ISO standards and recommendations.
Sanitation Compatible with all standard cleanroom sanitation and sterilization procedures, including Vaporized Hydrogen Peroxide (VHP).
Data Interface RS-232, Ethernet, and USB.
Laser and Collection Optics Patented metal ellipsoidal mirror uniquely mitigates the effect of particle shape (morphology) on sizing. No plastic laser or collection optics ensures the industry’s highest accuracy and stability of measurement. Contributes to product longevity and lowers Total Cost of Ownership.
Mirror Plating Rhodium plated metal ellipsoidal mirror uniquely ensures the highest resistance to damage, contamination, and decomposition when compared to chromium, gold, and other metals. Also, improves product longevity and Total Cost of Ownership (TCO).
Enclosure Stainless steel enclosure is impact resistant and easily cleaned and sanitized. Mitigates risk of biological contamination, and cross-contamination vs. plastic enclosures. Does not decompose like plastics, which adds to the particle burden of the cleanroom.
Display Large touchscreen display and large lettering. Easy to use interface. VERY quick response between screens—No frustrating delays.
Alarms Triggers at (i) Counts (User defined “Alert” and “Action” levels), (ii) Laser Status, and (iii) Flow Rate Deviation. 360 degree, user-configurable status and alarms (enable/disable, 5-colors, patterns, etc.)
Programmable Five Security Levels, 100 Programs, 100 User ID’s plus administrator with password security, 100 location IDs, and up to 10,000,000 samples. All models uniquely come standard with Unit-to-Unit cloning.
Printer Fully integrated thermal printer. No warts or plastic bubbles on the outside exterior that are difficult to sanitize.
Battery / Electrical CI-570 Series @ 5hours
Continuous at 100% duty cycle w/ Zero Count Filter Installed

Recharge Tim e: 3.5-4 hours w/ Internal charger
Wall Power: Universal 100-240 VAC
Dimension & Weight 8.38” x 7.4” x 9.48” = 587.9 cubic inches. Smallest portable on the market!
9.6 Lbs. with battery. The lightest industrial / pharmaceutical grade portable on the market!
Environmental Temperature: 0-36°C (32-97°F). Humidity: 10-90% relative humidity, non-condensing
Included Accessories Internal thermal printer, internal battery charger, battery, stainless steel or light blocker isokinetic probe, sample tubing, zero count filter, two rolls of thermal paper, IQ/OQ documentation, manual, external exhaust fitting, and USB flash drive.
Options Carrying case, probe stand, filter scanning probe, spare isokinetic probe, spare battery, validation documentation, external battery charger (comes with internal battery charger), and high-pressure diffusers (for sampling high pressure gases).
 
 
Accessories
 
Included with the purchase of every new unit is EVERYTHING you need to get started:
  • Internal Thermal Printer
  • Internal Battery Charger
  • Power Cord
  • Battery
  • Stainless steel isokinetic probe or light blocker probe
  • Sample Tubing (10 feet on all models except 100 LPM models, which get 6.5 feet)
  • Zero Count Filter
  • Two rolls of Standard Thermal Paper
  • Manual with IQ/OQ Documents
  • Cloning through USB or Ethernet port
  • External Exhaust Fitting as appropriate
  • USB Flash drive
  • Quick Start Guide

Optional Accessories
  • Rolls of Cleanroom Thermal Paper
  • Rolls of Standard Thermal Paper
  • CI-312 External Battery Charger
  • V-probes for filter scanning
  • Hard Shell Shipping Case (small or large)
  • Unit Validation Document
  • Spare Battery
  • Spare Zero Count Filter
  • Spare Stainless Steel ISO Probe
  • Spare Lightblocker ISO Probe
  • Probe Stand
  • High Pressure Diffuser
 
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in