Muser Apac Sdn Bhd
V Office 2, VO2-03-12,
Lingkaran SV,
Sunway Velocity,
Jalan Peel,
55100 Kuala Lumpur,
Malaysia.
V Office 2, VO2-03-12,
Lingkaran SV,
Sunway Velocity,
Jalan Peel,
55100 Kuala Lumpur,
Malaysia.
+603-2742 7468
PC950 Benchtop pH / Conductivity Meter Kit with TestBench | Apera by Muser
Previous | 5 / 16 | Next |
Apera PC950 Benchtop pH / Conductivity Meter Kit with TestBench
SKU: AI5624
SKU: AI5624
Description
Basic Features
- Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent stirrer, and buffer organizers altogether, streamlining the process of pH measurement and calibration.
- Simultaneous measurement of pH and conductivity/TDS/salinity
- Intuitive operating navigation with natural language and graphics
- Multi-language operating system (English, German, Spanish, Mandarin)
- Automatic calibration, automatic temperature compensation, self-diagnosis.
- Manual data logger with 200 groups of storage
pH Features
- Comes with the Swiss LabSen® 211 pH combination electrode and the MP500 temperature probe, achieving highly accurate measurements in the fastest manner
- 1 to 3 points automatic calibration with calibration instruction and self-diagnosis
- Automatically recognizes pH standard solution (1.68, 4.00, 7.00, 10.01, 12.45). 3 series buffer standards for selection: USA, NIST, China series, as well as user-customized standards.
- Automatically display electrode slope.
- Standard BNC pH connector, RCA connector for a temperature probe, NTC 30KΩ thermistor
Conductivity Features
- The 2401T-F glass conductivity/temp. electrode designed for research-level conductivity measurement from 0 to 200mS/cm at ±1% F.S accuracy
- 1 to 4 points automatic calibration with calibration instruction and self-diagnosis
- Automatically recognizes conductivity standard solution (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm).
- Standard BNC conductivity connector, RCA connector for a temperature probe, NTC 30KΩ thermistor
Technical Specifications
pH | Measuring Range | 0.00 ~ 14.00 pH |
Resolution | 0.1/0.01 pH | |
Accuracy | ±0.01 pH ±1 digit | |
Temperature Compensation Range | 0 ~ 100 ˚C (Auto. or Manual) | |
Calibration point | 1~3 points | |
mV | Measuring Range | ±2000mV |
Resolution | 1mV | |
Accuracy | ±0.1% FS ±1 digit | |
Cond. | Measuring Range |
Conductivity: 0~200 mS/cm, divided into five ranges, automatically switch measuring range. (0 to 19.99) μS/cm; (20.0 to 199.9) μS/cm; (200 to 1999) μS/cm; (2.00 to 19.99) mS/cm; (20.0 to 199.9) mS/cm TDS: (0 to 100) g/L; Salinity: (0 to 100) ppt |
Resolution |
0.01/0.1/1μS/cm 0.01/0.1 mS/cm |
|
Accuracy | ±1.0% FS ±1 digit | |
Temperature Compensation Range | 0 to 50˚C (Auto. or Manual) | |
Cell constant | 0.1 / 1 / 10 cm-1 | |
Temp. | Measuring Range | 0~100˚C |
Resolution | 0.1˚C | |
Accuracy | ±0.5˚C ±1 digit | |
Data Storage | 200 groups | |
Storage Content | Number, measuring value and temperature value | |
Power |
Input: 120V AC 60Hz; Output: DC9V/600mA, 2.7VA |
|
Dimension & Weight | Meter: (195×215×100 )mm / 0.9kg | |
Connector | BNC for pH, conductivity, and ORP; RCA for temperature | |
What's in the box? | PC950 Meter, TestBench, LabSen®211 pH/temp. electrode, 2401T-F conductivity/temp. electrode, 9V power adapter, flexible electrode holder, 50ml of pH buffers (4.00, 7.00, 10.01), 50ml of conductivity standards (84µS, 1413µS, 12.88mS), instruction manual |
Downloads